Ex D pressure transmitters with high accuracy for precise measurements
Explosion-proof pressure transducers of CM Sensormatic series IPS-T-XXX-YY-Z-WW-H measure and convert pressure into an electrical output signal. They are designed for operation in potentially explosive atmospheres at ambient temperatures from (-20) to +55 °C and atmospheric pressure P atm = 80 ÷ 110 kPa and an atmosphere containing about 21% oxygen by volume. Explosion-proof pressure sensors are suitable for operation in zones 1 and 2 of ATEX. They are developed in several versions of high accuracy classes: 0.075, 0.04 and 0.02 % of the range.
| Pressure ranges |
up to 35 bar absolute pressure; up to 400bar relative pressure |
Standards | BDS EN 60079-0:2018/AC:2020-02:2020 Explosive atmospheres. Part 0: Equipment. General requirements (IEC 60079-0:2017, Cor.1:2020) BDS EN 60079-1:2014 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" BDS EN 60079-31:2014 Explosive atmospheres. Part 31: Equipment protection against dust ignition by enclosure, type "t" (IEC 60079-31:2013) BDS EN 60079-11:2012 Explosive atmospheres. Part 11: Equipment protection by intrinsic safety, type "i" (IEC 60079-11:2011 + correction January 2012) |
| Power supply voltage | 10…24 V dc (max 30 Vdc) | Protection class |
IP 68 – 10 m H2O - BDS EN 60529:1991/A2:2013 – with cable from the manufacturer IP 65 – BDS EN 60529+А1- with housing IP 66 |
| Process connection | ¼ NPT; G1/4”BSP M; G3/8” BSP M; G1/2” BSP M; M20x1.5; G1”; G1¼” и други | Ellectrical connection | Cable gland М20х1.5, Ex db IIC Gb |
| Output signal | 4 ÷ 20 mA 2-wire scheme | Reverse polarity protection | Yes |
| Membrane | 316 Stainless steel | Weight | ~900g |
| Housing | Неръждаем, стомана 304S | Maximum pressure overload | x 1.5 |
| Working temperature | (-20)÷ 90 °C; (-20)÷ 100 °C; | Storage temperature | (-20) ÷ + 40 °C |
Make an inquiry
Additional information
| Brand |
|---|